SGS Hand Operated Cement Grouting Pump 7.5kw Manual Grouting Machine

Basic Properties
Place of Origin: China
Brand Name: Silk
Certification: CE, ISO, SGS
Model Number: BW60-10
Trading Properties
Minimum Order Quantity: 1 set
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 120 sets per month
Product Summary
Light weight advanced technology Hand Grouting Machine use friendly Hand Grouting Machine Safe Working Regulations for Pumps of Hand Grouting Machine: 1. During lifting of grouting pump, attention must be paid to prevent overturning accidents, and the wire rope should be firmly tied to the four ...

Product Details

Highlight:

SGS Hand Operated Cement Grouting Pump

,

7.5kw Manual Grouting Machine

,

Hand Operated Cement Grouting Pump 7.5kw

Name: Hand Grouting Machine
Motor (Kw): 7.5
Rated Pressure (Mpa): 10
Dia. Of Suction Pipe (Mm): 51
Dia. Of Discharge Pipe (Mm): 32
Model: BW60-10
Machine's Material: Carbon Steel
Warranty Years: 2
Product Description

Light weight advanced technology Hand Grouting Machine use friendly

 

Hand Grouting Machine

 

Safe Working Regulations for Pumps of Hand Grouting Machine:
1. During lifting of grouting pump, attention must be paid to prevent overturning accidents, and the wire rope should be firmly tied to the four corners of the base.
2. After the grouting pump and pump pipeline are installed, apply water under working pressure before starting to use, and check whether the installation quality and pressure safety device can work normally.
3. All wires connected to the grouting pump shall be overhead or loaded with rubber hose.
4. Grouting pump has no grounding wire, so it is absolutely forbidden to use it.
5. It is forbidden to continue working when there is any damage trace outside the grouting pump.
6. During the operation of the grouting pump, it is forbidden to carry out any repair, cleaning and oiling of the gear box.
7. It is forbidden to take down the protective cover of grouting pump without stopping and work without installing the protective cover.
8. It is forbidden to overpressure grouting pump and work for a long time.
9. When the grouting pump pressure does not drop to zero, it is forbidden to remove the air chamber, pressure gauge and pipeline.
10. When repairing and checking electric appliances such as motors, wires and pressure gauges, cut off the power supply.
11. For the grouting pump with casters, the casters should be adjusted to separate from the ground to prevent swimming during transportation and operation.

 

Technical parameters of Hand Grouting Machine:

 

Cylinder number 1
Bore diameter 80mm
Piston stroke 73mm
Diameter of suction pipe 51mm
Diameter of outlet pipe 32mm
Motor power 7.5kw
Main shaft speed 1440 r/min
Working pressure 10 Mpa

 

Structure of Hand Grouting Machine:

 

Hand grouting machine is mainly composed of pump body, pump frame, air chamber, shock-resistant pressure gauge, motor, V-belt and pulley cover.

The installation foundation of cement grouting pump should be smooth and not inclined.
The pump is fixed on the foundation with the foot screw to prevent the vibration of the pump during operation.

 

Preparations before pumping of Hand Grouting Machine:


After the pump has been stopped or reinstalled for a long time, the following preparations must be made before starting.
1. Check whether there is enough lubricating oil in each part.
2. Check whether the suction pipe of the filter is unblocked.
3. Check whether there is obstruction in the movement of each part.
4. Check the accuracy and reliability of the transmission mechanism.
5. Check the looseness of fasteners, especially the screw tightening of rubber piston locking nut, cross head and piston rod connection thread.
6. Check the suction height of the pump. The maximum suction height of the pump should not exceed 2.5 meters in areas below 1000 meters above sea level. In areas above 1000 meters above sea level, the suction height of the pump should be reduced according to the local atmospheric pressure reduction.
7.Check the position of the filter immersed in the mud tank. Generally, the mud level should be below 0.3-0.5 meters, and the filter should be no less than 0.5 meters away from the bottom of the mud tank.

 

Pictures of Hand Grouting Machine:

SGS Hand Operated Cement Grouting Pump 7.5kw Manual Grouting Machine 0

SGS Hand Operated Cement Grouting Pump 7.5kw Manual Grouting Machine 1SGS Hand Operated Cement Grouting Pump 7.5kw Manual Grouting Machine 2

Related Products
  • Orange ISO Cement Grout Pump Rational High Pressure Grouting Pump

    Advanced Technology Rational Structure High Pressure Grouting Machine Universal High Pressure Grouting Machine Characteristics of High Pressure Grouting Machine: High pressure grouting machine is composed of main pump, belt gear system, seat, safety stop valve, motor (diesel engine) and special ...
  • Green Gypsum Mortar Grout Pump 12 M3/H Floor Heating Backfill

    high Power Hydraulic type Gypsum Mortar Pump floor heating backfill Gypsum Mortar Pump Application of Gypsum Mortar Pump: 1. In construction engineering: horizontal and vertical conveying mortar or large area coating; 2. In chemical sector and transport pulp in the pulp and paper industry raw ...
  • SGS Mobile Concrete Pump Mini Concrete Pump Machine For Swimming Pool

    Portable Design Environmental Mobile Concrete Pump for swimming pool Mobile Concrete Pump PLC automatic control system of Mobile Concrete Pump: The core components of the electrical part is PLC chip, some important electrical components using imported brands, contactors, relays and button switches ...
  • Air Driven Concrete Spraying Machine 6m3/H Underground Shotcrete Sprayer

    tunnel subway use air driven Concrete Spraying Machine long service life Concrete Spraying Machine Maintenance of Concrete Spraying Machine: 1. Anti-stick cavity and discharging elbow with anti-stick function, generally will not bond at work, but after the end of each shift should open the rotor, ...

Send An Inquiry